The most important step in creating the simulation is to set the initial feed of material for the plant. The initial feed effects all calculations in the simulation.
If the actual feed gradation is known or is not available from the stored gradations, a new feed gradation can be added by clicking on Create New Feed
Learn More: Adjusting the Initial Feed Stream
The initial feed gradation is hard to measure because material sizes at this stage are typically larger than 8 inches (200 mm). The most important factor in determining the initial feed gradation is the amount of material that passes through the first screening point. For example, if the feed is to a grizzly feeder with a 5-inch bar opening (125 mm), then an accurate value for the percent of material passing 5 inches is required.